← All buyer notes

Feed procurement / ORGANICFEED

Particle Size in Feed Quotes: Match the Sieve Report

For an organic soy expeller cake or soybean meal quotation, a mesh number or an average particle size needs a clear test basis. Ask for the supplied form, the lot tested and the sieve report before treating two size claims as equivalent.

MUSE sourcing team
01

Confirm what material went into the test

Keep the material's supplied form separate from any preparation performed by the laboratory. Start the comparison with the producer, product and lot identification used in the quotation.

  • Record whether the material is cake, flakes, ground meal or pellets. Ask whether the test sample was measured as received or altered before analysis, and retain the preparation description.
  • K-State's lab instructions exclude pelleted feed and flag added fat as a potential source of screen blockage. Confirm the actual laboratory's method scope for your ingredient and supplied form before ordering the test.
02

Name the result, not just the number

K-State's MF3342 distinguishes geometric mean diameter dgw from geometric standard deviation Sgw. The former describes mean particle size in microns; the latter describes variation around it.

  • Ask the supplier to label the reported result: mean diameter, a specified sieve fraction or another clearly defined measure. Keep the original value and unit beside that definition.
  • A stated mean is different from a claim that every particle passes one opening. If the buying requirement concerns a particular coarse or fine fraction, request its result and whether it is reported as retained or passing.
03

Compare sieve openings and the procedure together

The K-State guide warns that the same sieve number can refer to different openings in different numbering systems, and that test settings can influence the result.

  • Request the sieve designation, actual opening sizes and the procedure reference or version. Do not fill in a missing opening from a bare mesh label.
  • Record the shaker, test duration, sieve agitators and any flow agent. Where two reports use different procedures, ask the quality team whether a comparison is valid or a matched-method retest is needed.
04

Turn the size requirement into a quote field

Before price comparison, have your manufacturing or nutrition lead define what size property matters for the intended handling or formulation. Put the agreed measure and acceptance criterion into the same specification sent to each supplier.

  • Use one row: product and lot | supplied form | sample preparation | laboratory and method | sieve openings | result definition and unit | reported distribution | agreed criterion | unresolved question.
  • Send the technical sheet and both size reports to our MUSE team through the contact options below. We can organise the supplier's missing fields while your quality team decides on technical acceptance.

Buyer questions

Do matching mesh numbers make two feed quotes equivalent?

Check the numbering system and actual opening first, then the reported measure and test procedure. Keep any mismatch open until the supplier or laboratory explains it.

Should I simply choose the smallest reported particle size?

Set the requirement for your own handling and formulation with the responsible manufacturing or nutrition lead. Compare the agreed measure, distribution and method instead of treating the smallest number as a universal buying target.

Continue your feed procurement brief

Primary references

  1. Kansas State University — MF3342 Evaluating Particle Size of Feedstuffs, definitions and method comparison ↗
  2. Kansas State University Swine Nutrition Lab — Particle Size Analysis Information and sample scope ↗

Privacy & analytics

OrganicFeed is operated by MUSE Information Services L.L.C-FZ, Dubai, UAE. With your permission, we use Google Analytics to measure visitors, sessions, page views and the channels that bring visitors to this website.

Analytics receives page paths, referring website domains, campaign labels, browser and device information, and approximate location. We remove URL query strings and fragments from page addresses sent by our code. We do not send inquiry messages, names or email addresses through this analytics code.

Analytics cookies help recognize a browser and its sessions. We set their lifetime to up to six months. Your analytics choice is stored in this browser for six months. Google may process analytics data outside your country. Google advertising storage, advertising user data and ad personalization remain disabled in our tag.

Choose Allow analytics or Decline analytics below. You can reopen Privacy & analytics in the footer at any time. Declining stops this website's analytics collection in this browser and removes its Google Analytics cookies. Website content and contact links remain available.

How Google uses information ↗

Privacy contact: leon@organicfeed.top