Identify which fibre result the supplier is offering
Ask the supplier to expand a field labelled only fibre or fiber. Keep the full analytical name and abbreviation together in the quotation, technical sheet and lot COA.
- CF — crude fibre: a specific fraction from traditional proximate analysis, with a different analytical definition from NDF and ADF. It is not a generic name for both.
- NDF — neutral detergent fibre: a cell-wall fraction containing primarily hemicellulose, cellulose and lignin.
- ADF — acid detergent fibre: a different cell-wall fraction containing primarily cellulose and lignin. It is not another name for NDF.
Put the method beside the named parameter
The parameter name alone does not fully describe how a result was obtained. Record the method reference and version, and preserve any qualifiers or suffixes used by the laboratory.
- Ask whether the reported value comes from a specified laboratory analytical procedure or a near-infrared reflectance spectroscopy (NIRS) prediction. Have the laboratory confirm suitability for the actual material.
- When suppliers use different procedures for the same named parameter, ask your quality team and laboratory whether the results are comparable. Do not assume that matching abbreviations establish matching methods.
- Keep each parameter's full name and abbreviation consistent across translations. A broad fibre heading must not merge CF, NDF and ADF into one field.
Align the reporting basis without changing the indicator
Confirm whether each result is reported on an as-received basis, including water, or a dry-matter basis, excluding water. The same percentage unit does not establish the same reporting basis.
- Record the unit and basis beside every result. If a basis conversion is needed, obtain the corresponding sample's moisture or dry-matter result and have the laboratory confirm the conversion.
- A change to dry-matter basis does not turn CF into NDF or ADF. If your requirement names NDF but the COA reports only CF, request the required NDF result rather than renaming the existing entry.
Send one clear fibre specification with the enquiry
For organic soy expeller cake, soybean meal or forage ingredients, send our MUSE team the supplier sheets, lot COAs and your required analytical fields through the contact options below. We can organise the missing supplier questions before you compare the offers.
- Have your nutrition or quality lead select the relevant indicators and acceptance criteria for the material and intended use. State whether each criterion is a maximum, minimum or range.
- Use one row per parameter: ingredient and lot | full parameter name and abbreviation | required criterion | unit | reporting basis | method and version | analytical procedure or NIRS prediction | COA reference | outstanding question.
- Keep CF, NDF and ADF on separate rows. Leave missing results awaiting confirmation and send the same agreed specification to each supplier.
Buyer questions
Can a dry-matter conversion turn crude fibre into NDF?
No. It changes the reporting basis for the same analytical parameter. Request the actual NDF result if NDF is required.
Does the lowest fibre result identify the best offer?
No. First match the indicator, material, method and reporting basis. Have the responsible nutrition or quality lead assess the result against the agreed requirements; a single fibre figure is not a complete purchasing assessment.