Identify how the reported CP was obtained
For nitrogen-based CP, the laboratory measures nitrogen and calculates CP using a conversion factor. Ask for the actual analytical method rather than treating CP as a direct measurement of true-protein mass.
- Request the method reference and version, including whether the laboratory used Kjeldahl or Dumas combustion analysis. If nitrogen was measured, request that result with its unit and sample reference.
- If CP is a near-infrared reflectance spectroscopy (NIRS) prediction, record it as such. Ask the laboratory which reference CP definition the prediction represents and whether its calibration covers this material. Record nitrogen as measured only when a nitrogen measurement is supplied.
Keep the actual factor and reporting basis visible
Request the nitrogen-to-protein factor actually used and its stated method or reporting basis. Keep it with the result; do not assume one factor applies to every material or replace it with a factor from an unrelated reference.
- Match the units and the as-received or dry-matter basis for nitrogen, CP and the purchasing specification. Ask the laboratory to explain any conversion needed before checking the calculation or comparing suppliers.
- Keep the original report and calculation explanation together. When methods, factors or result types differ, ask the laboratory and quality lead whether the results support the intended comparison and what further evidence is needed.
Separate CP from the protein information still needed
Nitrogen-derived CP can reflect contributions from both true-protein nitrogen and non-protein nitrogen (NPN). CP alone does not separate their contributions or establish protein availability. Matching CP figures therefore do not establish the same usable protein or formulation value.
- Ask your nutritionist which additional protein-quality, amino-acid or digestibility information is needed for the actual ingredient and intended use. Keep that assessment separate from confirmation of the reported CP calculation.
- Have the supplier provide the requested material-specific evidence for review. Keep the amount and source of any NPN unresolved unless supported by suitable evidence; the CP figure alone does not identify them.
Send a CP clarification row with your enquiry
For organic soy expeller cake, soybean meal or forage ingredients, send our MUSE team the producer sheet, lot COA and unanswered CP questions through the contact options below. We can organise the supplier and laboratory clarifications for your team's review.
- Use this row: ingredient and lot | report and sample identifiers | CP result, unit and basis | nitrogen-measured calculation or NIRS prediction | method and version | measured nitrogen, if available | actual factor and reference, where applicable | additional nutrition evidence requested | open question and owner.
- Send the same agreed CP reporting requirement to each supplier. Record the laboratory clarification and your nutrition or quality lead's assessment separately before using the data in the purchasing decision.
Buyer questions
Does a predicted CP value mean nitrogen was measured in this sample?
No. Ask the laboratory which results were measured and which were predicted. Keep an NIRS CP prediction identified as a prediction and request any available underlying laboratory evidence without relabelling a calculated value as a measurement.
Can the CP figure tell me how much NPN the lot contains?
Not by itself. CP does not partition the contributions of true-protein nitrogen and non-protein nitrogen. Have your nutrition or quality lead specify any further evidence needed for that question.