{
  "$schema": "https://organicfeed.top/api/schema.json#/$defs/page",
  "schema_version": "1",
  "resource_type": "page",
  "generated_at": "2026-11-07T04:17:46Z",
  "content_updated_at": "2026-10-24",
  "id": "blog--organic-feed-coa-nd-loq-reporting-limits",
  "language": "en",
  "path": "/en/blog/organic-feed-coa-nd-loq-reporting-limits/",
  "kind": "buyer_blog",
  "title": "ND or <LOQ on a Feed COA: Why Buyers Must Not Enter Zero",
  "description": "Clarify ND, not detected and <LOQ on feed COAs. Request the applicable limits, units, reporting basis and laboratory explanation before a purchasing review.",
  "canonical_url": "https://organicfeed.top/en/blog/organic-feed-coa-nd-loq-reporting-limits/",
  "api_url": "https://organicfeed.top/api/pages/en/blog--organic-feed-coa-nd-loq-reporting-limits.json",
  "content_modified": "2026-10-24",
  "text": "← All buyer notes (https://organicfeed.top/en/blog/)\n\nFeed procurement / ORGANICFEED\n\nND or <LOQ on a Feed COA: Why Buyers Must Not Enter Zero\n\nFor concentration results on a feed COA, ND, not detected and <LOQ must not be treated as a measured zero. We first ask what the entry means in that report and which analytical limits apply. The notation alone does not establish absence or settle a lot-acceptance decision.\n\n2026-10-24 MUSE sourcing team\n\n01\n\nKeep the original entry and read its definition\n\nCopy the exact test or analyte name and result text from the laboratory report, including any less-than sign, qualifier and footnote. Ask the issuing laboratory to explain an undefined entry.\n\nFor ND or not detected, request the report's definition and the applicable numerical threshold. Do not assume every laboratory uses ND to mean below LOD or below LOQ.\n\nKeep a missing or unreported test separate from a non-detection. Ask whether the requested item was tested and obtain its report entry.\n\n02\n\nSeparate detection from quantification\n\nLOD, the limit of detection, describes detection capability. LOQ, the limit of quantitation or quantification, concerns the ability to give a quantitative result with acceptable precision. These address different questions.\n\nAn entry of <LOQ may include an analyte that was detected but could not be quantified at the required performance level. Ask the laboratory what the entry establishes for this result; it does not by itself prove absence.\n\nRequest the applicable LOD, LOQ and any separate reporting limit for each requested analyte, with units. Ask whether these describe the complete analytical method and actual reported result, rather than only an instrument's detection capability.\n\n03\n\nGive the quality lead the limits and reporting conditions\n\nKeep the material, sample and lot link, method reference and version, unit, reporting basis and laboratory notes together. Where as-received or dry-matter reporting is used, identify it explicitly for both the result and the applicable limit.\n\nAsk the laboratory to clarify the limits applicable to this material and result, including any qualifications stated in the report. Request an explanation of any unit or basis conversion needed for the review.\n\nGive your quality lead the agreed purchasing criterion, original result and applicable limits. Ask whether the report's qualifications and the applicable decision rule support the intended purchasing decision, and what clarification or further evidence is needed.\n\n04\n\nSend one clarification row per test item\n\nFor organic soy expeller cake, soybean meal or forage ingredients, send our MUSE team the complete report and unresolved items through the contact options below. We can organise supplier questions and requests for the issuing laboratory's explanation.\n\nUse this row: ingredient and lot | report and sample identifiers | test or analyte | original result text | unit and basis | method and version | applicable LOD, LOQ and reporting limit | report definition and notes | question and responsible person.\n\nKeep the original report beside written clarifications. Record the quality lead's purchasing decision separately; retain unresolved questions without filling them with a zero or an assumed acceptance.\n\n→\n\nBuyer takeaway\n\nPreserve the qualified result, obtain the laboratory's definitions and applicable limits, and give the complete evidence to the quality lead before deciding on the purchase.\n\nBuyer questions\n\nCan I put zero in the comparison sheet when the COA says ND?\n\nKeep ND and its report-defined meaning, threshold, unit and basis. It is not a measured zero. If a calculation needs a numerical input, ask your quality lead how that qualified result should be handled and preserve the original entry.\n\nDo two suppliers reporting ND provide equivalent evidence?\n\nNot necessarily. Compare the exact analyte, method, material, applicable limits, units, reporting basis and report definitions. Two identical abbreviations can represent different reporting conditions.\n\nContinue your feed procurement brief\n\nOrganic feed ingredients sourcing for Europe and the Gulf ↗ (https://organicfeed.top/en/organic-feed-ingredients/)\n\nOrganic soy expeller cake vs soybean meal: Gulf buyer comparison ↗ (https://organicfeed.top/en/organic-soy-expeller-cake/)\n\nRFQ / FEED INGREDIENTS\n\nSend your buying brief\n\nIngredient and intended species / organic standard and destination market / target protein, moisture, fibre and oil specification / quantity and packaging / origin preference / delivery port and window / required organic, halal, COA and traceability documents.\n\nCopy buyer brief ↗ WhatsApp ↗ (https://wa.me/971555671672?text=What%20to%20send%20with%20your%20inquiry%0AIngredient%20and%20intended%20species%20/%20organic%20standard%20and%20destination%20market%20/%20target%20protein%2C%20moisture%2C%20fibre%20and%20oil%20specification%20/%20quantity%20and%20packaging%20/%20origin%20preference%20/%20delivery%20port%20and%20window%20/%20required%20organic%2C%20halal%2C%20COA%20and%20traceability%20documents.) Email ↗ (mailto:leon@organicfeed.top)\n\nPrimary references\n\nFDA — Chemical-method validation guidance, Appendix 1: LOD, LOQ and MDL ↗ (https://www.fda.gov/media/81810/download)\n\nUSGS — Minimum reporting level and interpretation of non-detections ↗ (https://water.usgs.gov/owq/OFR_99-193/minimum.html)",
  "headings": [
    {
      "level": 1,
      "text": "ND or <LOQ on a Feed COA: Why Buyers Must Not Enter Zero"
    },
    {
      "level": 2,
      "text": "Keep the original entry and read its definition"
    },
    {
      "level": 2,
      "text": "Separate detection from quantification"
    },
    {
      "level": 2,
      "text": "Give the quality lead the limits and reporting conditions"
    },
    {
      "level": 2,
      "text": "Send one clarification row per test item"
    },
    {
      "level": 2,
      "text": "Buyer questions"
    },
    {
      "level": 2,
      "text": "Continue your feed procurement brief"
    },
    {
      "level": 2,
      "text": "Send your buying brief"
    },
    {
      "level": 2,
      "text": "Primary references"
    }
  ],
  "links": [
    {
      "text": "← All buyer notes",
      "url": "https://organicfeed.top/en/blog/"
    },
    {
      "text": "Organic feed ingredients sourcing for Europe and the Gulf ↗",
      "url": "https://organicfeed.top/en/organic-feed-ingredients/"
    },
    {
      "text": "Organic soy expeller cake vs soybean meal: Gulf buyer comparison ↗",
      "url": "https://organicfeed.top/en/organic-soy-expeller-cake/"
    },
    {
      "text": "WhatsApp ↗",
      "url": "https://wa.me/971555671672?text=What%20to%20send%20with%20your%20inquiry%0AIngredient%20and%20intended%20species%20/%20organic%20standard%20and%20destination%20market%20/%20target%20protein%2C%20moisture%2C%20fibre%20and%20oil%20specification%20/%20quantity%20and%20packaging%20/%20origin%20preference%20/%20delivery%20port%20and%20window%20/%20required%20organic%2C%20halal%2C%20COA%20and%20traceability%20documents."
    },
    {
      "text": "Email ↗",
      "url": "mailto:leon@organicfeed.top"
    },
    {
      "text": "FDA — Chemical-method validation guidance, Appendix 1: LOD, LOQ and MDL ↗",
      "url": "https://www.fda.gov/media/81810/download"
    },
    {
      "text": "USGS — Minimum reporting level and interpretation of non-detections ↗",
      "url": "https://water.usgs.gov/owq/OFR_99-193/minimum.html"
    }
  ],
  "questions": [
    {
      "question": "Can I put zero in the comparison sheet when the COA says ND?",
      "answer": "Keep ND and its report-defined meaning, threshold, unit and basis. It is not a measured zero. If a calculation needs a numerical input, ask your quality lead how that qualified result should be handled and preserve the original entry."
    },
    {
      "question": "Do two suppliers reporting ND provide equivalent evidence?",
      "answer": "Not necessarily. Compare the exact analyte, method, material, applicable limits, units, reporting basis and report definitions. Two identical abbreviations can represent different reporting conditions."
    }
  ],
  "citations": [
    "https://www.fda.gov/media/81810/download",
    "https://water.usgs.gov/owq/OFR_99-193/minimum.html"
  ],
  "content_sha256": "adcca397962f72ec120bafc9936ff1a768bb8585dbde59663a6a02c7fee29663"
}
